3.3.2.2. NXarpes

Status:

application definition, extends NXobject

Description:

This is an application definition for angular resolved photo electron spectrosco ...

This is an application definition for angular resolved photo electron spectroscopy.

It has been drawn up with hemispherical electron analysers in mind.

Symbols:

No symbol table

Groups cited:

NXdata, NXdetector, NXentry, NXinstrument, NXmonochromator, NXsample, NXsource

Structure:

ENTRY: (required) NXentry

@entry: (required) NX_CHAR

NeXus convention is to use "entry1", "entry2", ... ...

NeXus convention is to use “entry1”, “entry2”, … for analysis software to locate each entry.

title: (required) NX_CHAR

start_time: (required) NX_DATE_TIME

definition: (required) NX_CHAR

Official NeXus NXDL schema to which this file conforms. ...

Official NeXus NXDL schema to which this file conforms.

Obligatory value: NXarpes

INSTRUMENT: (required) NXinstrument

SOURCE: (required) NXsource

type: (required) NX_CHAR

name: (required) NX_CHAR

probe: (required) NX_CHAR

Obligatory value: x-ray

monochromator: (required) NXmonochromator

energy: (required) NX_NUMBER {units=NX_ENERGY}

analyser: (required) NXdetector

data: (required) NX_NUMBER

lens_mode: (required) NX_CHAR

setting for the electron analyser lens

acquisition_mode: (required) NX_CHAR

Any of these values: swept | fixed

entrance_slit_shape: (required) NX_CHAR

Any of these values: curved | straight

entrance_slit_setting: (required) NX_NUMBER {units=NX_ANY}

dial setting of the entrance slit

entrance_slit_size: (required) NX_NUMBER {units=NX_LENGTH}

size of the entrance slit

pass_energy: (required) NX_NUMBER {units=NX_ENERGY}

energy of the electrons on the mean path of the analyser

time_per_channel: (required) NX_NUMBER {units=NX_TIME}

todo: define more clearly

angles: (required) NX_NUMBER {units=NX_ANGLE}

Angular axis of the analyser data ...

Angular axis of the analyser data which dimension the axis applies to is defined using the normal NXdata methods.

energies: (required) NX_NUMBER {units=NX_ENERGY}

Energy axis of the analyser data ...

Energy axis of the analyser data which dimension the axis applies to is defined using the normal NXdata methods.

sensor_size: (required) NX_INT (Rank: 1, Dimensions: [2])

number of raw active elements in each dimension

region_origin: (required) NX_INT (Rank: 1, Dimensions: [2])

origin of rectangular region selected for readout

region_size: (required) NX_INT (Rank: 1, Dimensions: [2])

size of rectangular region selected for readout

SAMPLE: (required) NXsample

name: (required) NX_CHAR

Descriptive name of sample

temperature: (required) NX_NUMBER {units=NX_TEMPERATURE}

DATA: (required) NXdata

Hypertext Anchors

List of hypertext anchors for all groups, fields, attributes, and links defined in this class.

NXDL Source:

https://github.com/nexusformat/definitions/blob/main/applications/NXarpes.nxdl.xml