.. auto-generated by dev_tools.docs.nxdl from the NXDL source contributed_definitions/NXmpes.nxdl.xml -- DO NOT EDIT .. index:: ! NXmpes (application definition) ! mpes (application definition) see: mpes (application definition); NXmpes .. _NXmpes: ====== NXmpes ====== .. Contributors List .. |contrib_name| replace:: Rubel|RubelMozumder|https://avatars.githubusercontent.com/u/32923026?v=4|2023-06-14 .. |contrib_name| replace:: Domna|domna|https://avatars.githubusercontent.com/u/1014422?v=4|2023-02-01 .. |contrib_name| replace:: Kuehbachm|mkuehbach|https://avatars.githubusercontent.com/u/14091504?v=4|2022-03-31 **Status**: application definition, extends :ref:`NXobject` **Description**: .. collapse:: This is the most general application definition for multidimensional ... This is the most general application definition for multidimensional photoelectron spectroscopy. **Symbols**: No symbol table **Groups cited**: :ref:`NXaperture`, :ref:`NXbeam`, :ref:`NXcalibration`, :ref:`NXcollectioncolumn`, :ref:`NXdata`, :ref:`NXdetector`, :ref:`NXelectronanalyser`, :ref:`NXenergydispersion`, :ref:`NXentry`, :ref:`NXinstrument`, :ref:`NXmanipulator`, :ref:`NXnote`, :ref:`NXprocess`, :ref:`NXsample`, :ref:`NXsource`, :ref:`NXuser` .. index:: NXentry (base class); used in application definition, NXuser (base class); used in application definition, NXinstrument (base class); used in application definition, NXsource (base class); used in application definition, NXbeam (base class); used in application definition, NXelectronanalyser (base class); used in application definition, NXcollectioncolumn (base class); used in application definition, NXaperture (base class); used in application definition, NXenergydispersion (base class); used in application definition, NXdetector (base class); used in application definition, NXdata (base class); used in application definition, NXmanipulator (base class); used in application definition, NXprocess (base class); used in application definition, NXcalibration (base class); used in application definition, NXsample (base class); used in application definition, NXnote (base class); used in application definition **Structure**: .. _/NXmpes/ENTRY-group: **ENTRY**: (required) :ref:`NXentry` .. _/NXmpes/ENTRY/title-field: .. index:: title (field) **title**: (required) :ref:`NX_CHAR ` :ref:`⤆ ` .. _/NXmpes/ENTRY/start_time-field: .. index:: start_time (field) **start_time**: (required) :ref:`NX_DATE_TIME ` :ref:`⤆ ` Datetime of the start of the measurement. .. _/NXmpes/ENTRY/definition-field: .. index:: definition (field) **definition**: (required) :ref:`NX_CHAR ` :ref:`⤆ ` Obligatory value: ``NXmpes`` .. _/NXmpes/ENTRY/definition@version-attribute: .. index:: version (field attribute) **@version**: (required) :ref:`NX_CHAR ` :ref:`⤆ ` .. _/NXmpes/ENTRY/USER-group: **USER**: (required) :ref:`NXuser` :ref:`⤆ ` .. collapse:: Contact information of at least the user of the instrument or the investigat ... Contact information of at least the user of the instrument or the investigator who performed this experiment. Adding multiple users if relevant is recommended. .. _/NXmpes/ENTRY/USER/name-field: .. index:: name (field) **name**: (required) :ref:`NX_CHAR ` :ref:`⤆ ` Name of the user. .. _/NXmpes/ENTRY/USER/affiliation-field: .. index:: affiliation (field) **affiliation**: (recommended) :ref:`NX_CHAR ` :ref:`⤆ ` .. collapse:: Name of the affiliation of the user at the point in time when the experime ... Name of the affiliation of the user at the point in time when the experiment was performed. .. _/NXmpes/ENTRY/USER/address-field: .. index:: address (field) **address**: (recommended) :ref:`NX_CHAR ` :ref:`⤆ ` .. collapse:: Full address (street, street number, ZIP, city, country) of the user's ... Full address (street, street number, ZIP, city, country) of the user's affiliation. .. _/NXmpes/ENTRY/USER/email-field: .. index:: email (field) **email**: (required) :ref:`NX_CHAR ` :ref:`⤆ ` Email address of the user. .. _/NXmpes/ENTRY/USER/orcid-field: .. index:: orcid (field) **orcid**: (recommended) :ref:`NX_CHAR ` :ref:`⤆ ` Author ID defined by https://orcid.org/. .. _/NXmpes/ENTRY/INSTRUMENT-group: **INSTRUMENT**: (required) :ref:`NXinstrument` :ref:`⤆ ` .. _/NXmpes/ENTRY/INSTRUMENT/energy_resolution-field: .. index:: energy_resolution (field) **energy_resolution**: (required) :ref:`NX_FLOAT ` {units=\ :ref:`NX_ENERGY `} .. _/NXmpes/ENTRY/INSTRUMENT/SOURCE-group: **SOURCE**: (required) :ref:`NXsource` :ref:`⤆ ` .. collapse:: The source used to generate the primary photons. Properties refer strictly ... The source used to generate the primary photons. Properties refer strictly to parameters of the source, not of the output beam. For example, the energy of the source is not the optical power of the beam, but the energy of the electron beam in a synchrotron and so on. .. _/NXmpes/ENTRY/INSTRUMENT/SOURCE/type-field: .. index:: type (field) **type**: (required) :ref:`NX_CHAR ` :ref:`⤆ ` Any of these values: * ``Synchrotron X-ray Source`` * ``Rotating Anode X-ray`` * ``Fixed Tube X-ray`` * ``UV Laser`` * ``Free-Electron Laser`` * ``Optical Laser`` * ``UV Plasma Source`` * ``Metal Jet X-ray`` * ``HHG laser`` .. _/NXmpes/ENTRY/INSTRUMENT/SOURCE/name-field: .. index:: name (field) **name**: (required) :ref:`NX_CHAR ` :ref:`⤆ ` .. _/NXmpes/ENTRY/INSTRUMENT/SOURCE/probe-field: .. index:: probe (field) **probe**: (required) :ref:`NX_CHAR ` :ref:`⤆ ` .. collapse:: Type of probe. In photoemission it's always photons, so the full NIAC li ... Type of probe. In photoemission it's always photons, so the full NIAC list is restricted. Any of these values: ``x-ray`` | ``ultraviolet`` | ``visible light`` .. _/NXmpes/ENTRY/INSTRUMENT/BEAM-group: **BEAM**: (required) :ref:`NXbeam` :ref:`⤆ ` .. _/NXmpes/ENTRY/INSTRUMENT/BEAM/distance-field: .. index:: distance (field) **distance**: (required) :ref:`NX_NUMBER ` {units=\ :ref:`NX_LENGTH `} Distance of the point of evaluation of the beam from the sample surface. .. _/NXmpes/ENTRY/INSTRUMENT/BEAM/incident_energy-field: .. index:: incident_energy (field) **incident_energy**: (required) :ref:`NX_FLOAT ` {units=\ :ref:`NX_ENERGY `} :ref:`⤆ ` .. _/NXmpes/ENTRY/INSTRUMENT/BEAM/incident_energy_spread-field: .. index:: incident_energy_spread (field) **incident_energy_spread**: (recommended) :ref:`NX_NUMBER ` {units=\ :ref:`NX_ENERGY `} .. _/NXmpes/ENTRY/INSTRUMENT/BEAM/incident_polarization-field: .. index:: incident_polarization (field) **incident_polarization**: (recommended) :ref:`NX_NUMBER ` {units=\ :ref:`NX_ANY `} :ref:`⤆ ` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER-group: **ELECTRONANALYSER**: (required) :ref:`NXelectronanalyser` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/description-field: .. index:: description (field) **description**: (required) :ref:`NX_CHAR ` :ref:`⤆ ` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/energy_resolution-field: .. index:: energy_resolution (field) **energy_resolution**: (recommended) :ref:`NX_FLOAT ` {units=\ :ref:`NX_ENERGY `} :ref:`⤆ ` .. collapse:: Energy resolution of the analyser with the current setting. May be linke ... Energy resolution of the analyser with the current setting. May be linked from a NXcalibration. .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/fast_axes-field: .. index:: fast_axes (field) **fast_axes**: (recommended) :ref:`NX_CHAR ` :ref:`⤆ ` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/slow_axes-field: .. index:: slow_axes (field) **slow_axes**: (recommended) :ref:`NX_CHAR ` :ref:`⤆ ` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/COLLECTIONCOLUMN-group: **COLLECTIONCOLUMN**: (required) :ref:`NXcollectioncolumn` :ref:`⤆ ` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/COLLECTIONCOLUMN/scheme-field: .. index:: scheme (field) **scheme**: (required) :ref:`NX_CHAR ` :ref:`⤆ ` .. collapse:: Scheme of the electron collection column. ... Scheme of the electron collection column. Any of these values: * ``Standard`` * ``Angular dispersive`` * ``Selective area`` * ``Deflector`` * ``PEEM`` * ``Momentum Microscope`` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/COLLECTIONCOLUMN/mode-field: .. index:: mode (field) **mode**: (recommended) :ref:`NX_CHAR ` :ref:`⤆ ` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/COLLECTIONCOLUMN/projection-field: .. index:: projection (field) **projection**: (recommended) :ref:`NX_CHAR ` :ref:`⤆ ` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/COLLECTIONCOLUMN/field_aperture-group: **field_aperture**: (optional) :ref:`NXaperture` :ref:`⤆ ` .. collapse:: The size and position of the field aperture inserted in the column. To ... The size and position of the field aperture inserted in the column. To add additional or other apertures use the APERTURE group of NXcollectioncolumn. .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/COLLECTIONCOLUMN/contrast_aperture-group: **contrast_aperture**: (optional) :ref:`NXaperture` :ref:`⤆ ` .. collapse:: The size and position of the contrast aperture inserted in the column. ... The size and position of the contrast aperture inserted in the column. To add additional or other apertures use the APERTURE group of NXcollectioncolumn. .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/ENERGYDISPERSION-group: **ENERGYDISPERSION**: (required) :ref:`NXenergydispersion` :ref:`⤆ ` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/ENERGYDISPERSION/scheme-field: .. index:: scheme (field) **scheme**: (required) :ref:`NX_CHAR ` :ref:`⤆ ` Any of these values: * ``tof`` * ``hemispherical`` * ``double hemispherical`` * ``cylindrical mirror`` * ``display mirror`` * ``retarding grid`` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/ENERGYDISPERSION/pass_energy-field: .. index:: pass_energy (field) **pass_energy**: (required) :ref:`NX_FLOAT ` {units=\ :ref:`NX_ENERGY `} :ref:`⤆ ` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/ENERGYDISPERSION/energy_scan_mode-field: .. index:: energy_scan_mode (field) **energy_scan_mode**: (required) :ref:`NX_CHAR ` :ref:`⤆ ` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/ENERGYDISPERSION/entrance_slit-group: **entrance_slit**: (optional) :ref:`NXaperture` :ref:`⤆ ` .. collapse:: Size, position and shape of the entrance slit in dispersive analyzers. ... Size, position and shape of the entrance slit in dispersive analyzers. To add additional or other slits use the APERTURE group of NXenergydispersion. .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/ENERGYDISPERSION/exit_slit-group: **exit_slit**: (optional) :ref:`NXaperture` :ref:`⤆ ` .. collapse:: Size, position and shape of the exit slit in dispersive analyzers. To ... Size, position and shape of the exit slit in dispersive analyzers. To add additional or other slits use the APERTURE group of NXenergydispersion. .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/DETECTOR-group: **DETECTOR**: (required) :ref:`NXdetector` :ref:`⤆ ` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/DETECTOR/amplifier_type-field: .. index:: amplifier_type (field) **amplifier_type**: (recommended) :ref:`NX_CHAR ` .. collapse:: Type of electron amplifier in the first amplification step. ... Type of electron amplifier in the first amplification step. Any of these values: ``MCP`` | ``channeltron`` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/DETECTOR/detector_type-field: .. index:: detector_type (field) **detector_type**: (recommended) :ref:`NX_CHAR ` .. collapse:: Description of the detector type. ... Description of the detector type. Any of these values: * ``DLD`` * ``Phosphor+CCD`` * ``Phosphor+CMOS`` * ``ECMOS`` * ``Anode`` * ``Multi-anode`` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/DETECTOR/DATA-group: **DATA**: (recommended) :ref:`NXdata` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/DETECTOR/DATA@signal-attribute: .. index:: signal (group attribute) **@signal**: (required) :ref:`NX_CHAR ` :ref:`⤆ ` Obligatory value: ``raw`` .. _/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/DETECTOR/DATA/raw-field: .. index:: raw (field) **raw**: (required) :ref:`NX_NUMBER ` Raw data before calibration. .. _/NXmpes/ENTRY/INSTRUMENT/MANIPULATOR-group: **MANIPULATOR**: (optional) :ref:`NXmanipulator` Manipulator for positioning of the sample. .. _/NXmpes/ENTRY/INSTRUMENT/MANIPULATOR/sample_temperature-field: .. index:: sample_temperature (field) **sample_temperature**: (recommended) :ref:`NX_FLOAT ` {units=\ :ref:`NX_TEMPERATURE `} :ref:`⤆ ` .. _/NXmpes/ENTRY/INSTRUMENT/MANIPULATOR/drain_current-field: .. index:: drain_current (field) **drain_current**: (recommended) :ref:`NX_FLOAT ` {units=\ :ref:`NX_CURRENT `} :ref:`⤆ ` .. _/NXmpes/ENTRY/INSTRUMENT/MANIPULATOR/sample_bias-field: .. index:: sample_bias (field) **sample_bias**: (recommended) :ref:`NX_FLOAT ` {units=\ :ref:`NX_CURRENT `} :ref:`⤆ ` .. _/NXmpes/ENTRY/PROCESS-group: **PROCESS**: (required) :ref:`NXprocess` :ref:`⤆ ` .. collapse:: Document an event of data processing, reconstruction, or analysis for this d ... Document an event of data processing, reconstruction, or analysis for this data. Describe the appropriate axis calibrations for your experiment using one or more of the following NXcalibrations .. _/NXmpes/ENTRY/PROCESS/energy_calibration-group: **energy_calibration**: (optional) :ref:`NXcalibration` .. _/NXmpes/ENTRY/PROCESS/energy_calibration/applied-field: .. index:: applied (field) **applied**: (required) :ref:`NX_BOOLEAN ` :ref:`⤆ ` Has an energy calibration been applied? .. _/NXmpes/ENTRY/PROCESS/energy_calibration/calibrated_axis-field: .. index:: calibrated_axis (field) **calibrated_axis**: (recommended) :ref:`NX_FLOAT ` :ref:`⤆ ` This is the calibrated energy axis to be used for data plotting. .. _/NXmpes/ENTRY/PROCESS/angular_calibration-group: **angular_calibration**: (optional) :ref:`NXcalibration` .. _/NXmpes/ENTRY/PROCESS/angular_calibration/applied-field: .. index:: applied (field) **applied**: (required) :ref:`NX_BOOLEAN ` :ref:`⤆ ` Has an angular calibration been applied? .. _/NXmpes/ENTRY/PROCESS/angular_calibration/calibrated_axis-field: .. index:: calibrated_axis (field) **calibrated_axis**: (recommended) :ref:`NX_FLOAT ` :ref:`⤆ ` This is the calibrated angular axis to be used for data plotting. .. _/NXmpes/ENTRY/PROCESS/spatial_calibration-group: **spatial_calibration**: (optional) :ref:`NXcalibration` .. _/NXmpes/ENTRY/PROCESS/spatial_calibration/applied-field: .. index:: applied (field) **applied**: (required) :ref:`NX_BOOLEAN ` :ref:`⤆ ` Has an spatial calibration been applied? .. _/NXmpes/ENTRY/PROCESS/spatial_calibration/calibrated_axis-field: .. index:: calibrated_axis (field) **calibrated_axis**: (recommended) :ref:`NX_FLOAT ` :ref:`⤆ ` This is the calibrated spatial axis to be used for data plotting. .. _/NXmpes/ENTRY/PROCESS/momentum_calibration-group: **momentum_calibration**: (optional) :ref:`NXcalibration` .. _/NXmpes/ENTRY/PROCESS/momentum_calibration/applied-field: .. index:: applied (field) **applied**: (required) :ref:`NX_BOOLEAN ` :ref:`⤆ ` Has an momentum calibration been applied? .. _/NXmpes/ENTRY/PROCESS/momentum_calibration/calibrated_axis-field: .. index:: calibrated_axis (field) **calibrated_axis**: (recommended) :ref:`NX_FLOAT ` :ref:`⤆ ` This is the momentum axis to be used for data plotting. .. _/NXmpes/ENTRY/SAMPLE-group: **SAMPLE**: (required) :ref:`NXsample` :ref:`⤆ ` .. _/NXmpes/ENTRY/SAMPLE/name-field: .. index:: name (field) **name**: (required) :ref:`NX_CHAR ` :ref:`⤆ ` .. _/NXmpes/ENTRY/SAMPLE/chemical_formula-field: .. index:: chemical_formula (field) **chemical_formula**: (recommended) :ref:`NX_CHAR ` :ref:`⤆ ` .. collapse:: The chemical formula of the sample. For mixtures use the NXsample_componen ... The chemical formula of the sample. For mixtures use the NXsample_component group in NXsample instead. .. _/NXmpes/ENTRY/SAMPLE/atom_types-field: .. index:: atom_types (field) **atom_types**: (recommended) :ref:`NX_CHAR ` .. collapse:: List of comma-separated elements from the periodic table ... List of comma-separated elements from the periodic table that are contained in the sample. If the sample substance has multiple components, all elements from each component must be included in `atom_types`. .. _/NXmpes/ENTRY/SAMPLE/preparation_date-field: .. index:: preparation_date (field) **preparation_date**: (recommended) :ref:`NX_DATE_TIME ` :ref:`⤆ ` .. collapse:: Date of preparation of the sample for the XPS experiment (i.e. cleaving, l ... Date of preparation of the sample for the XPS experiment (i.e. cleaving, last annealing). .. _/NXmpes/ENTRY/SAMPLE/temperature-field: .. index:: temperature (field) **temperature**: (required) :ref:`NX_FLOAT ` {units=\ :ref:`NX_TEMPERATURE `} :ref:`⤆ ` .. collapse:: In the case of a fixed temperature measurement this is the scalar temperat ... In the case of a fixed temperature measurement this is the scalar temperature of the sample. In the case of an experiment in which the temperature is changed and recoded, this is an array of length m of temperatures. This should be a link to /entry/instrument/manipulator/sample_temperature. .. _/NXmpes/ENTRY/SAMPLE/situation-field: .. index:: situation (field) **situation**: (required) :ref:`NX_CHAR ` :ref:`⤆ ` Any of these values: * ``vacuum`` * ``inert atmosphere`` * ``oxidising atmosphere`` * ``reducing atmosphere`` .. _/NXmpes/ENTRY/SAMPLE/gas_pressure-field: .. index:: gas_pressure (field) **gas_pressure**: (required) :ref:`NX_FLOAT ` {units=\ :ref:`NX_PRESSURE `} .. _/NXmpes/ENTRY/SAMPLE/sample_history-group: **sample_history**: (recommended) :ref:`NXnote` .. collapse:: A descriptor to keep track of the treatment of the sample before entering ... A descriptor to keep track of the treatment of the sample before entering the photoemission experiment. Ideally, a full report of the previous operations, in any format (NXnote allows to add pictures, audio, movies). Alternatively, a reference to the location or a unique identifier or other metadata file. In the case these are not available, free-text description. .. _/NXmpes/ENTRY/SAMPLE/preparation_description-group: **preparation_description**: (required) :ref:`NXnote` .. collapse:: Description of the surface preparation technique for the XPS experiment, i ... Description of the surface preparation technique for the XPS experiment, i.e. UHV cleaving, in-situ growth, sputtering/annealing etc. Ideally, a full report of the previous operations, in any format(NXnote allows to add pictures, audio, movies). Alternatively, a reference to the location or a unique identifier or other metadata file. In the case these are not available, free-text description. .. _/NXmpes/ENTRY/DATA-group: **DATA**: (required) :ref:`NXdata` :ref:`⤆ ` .. _/NXmpes/ENTRY/DATA@signal-attribute: .. index:: signal (group attribute) **@signal**: (required) :ref:`NX_CHAR ` :ref:`⤆ ` Obligatory value: ``data`` .. _/NXmpes/ENTRY/DATA/data-field: .. index:: data (field) **data**: (required) :ref:`NX_NUMBER ` {units=\ :ref:`NX_ANY `} :ref:`⤆ ` .. collapse:: Represents a measure of one- or more-dimensional photoemission counts, whe ... Represents a measure of one- or more-dimensional photoemission counts, where the varied axis may be for example energy, momentum, spatial coordinate, pump-probe delay, spin index, temperature, etc. The axes traces should be linked to the actual encoder position in NXinstrument or calibrated axes in NXprocess. Hypertext Anchors ----------------- List of hypertext anchors for all groups, fields, attributes, and links defined in this class. * :ref:`/NXmpes/ENTRY-group ` * :ref:`/NXmpes/ENTRY/DATA-group ` * :ref:`/NXmpes/ENTRY/DATA/data-field ` * :ref:`/NXmpes/ENTRY/DATA@signal-attribute ` * :ref:`/NXmpes/ENTRY/definition-field ` * :ref:`/NXmpes/ENTRY/definition@version-attribute ` * :ref:`/NXmpes/ENTRY/INSTRUMENT-group ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/BEAM-group ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/BEAM/distance-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/BEAM/incident_energy-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/BEAM/incident_energy_spread-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/BEAM/incident_polarization-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER-group ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/COLLECTIONCOLUMN-group ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/COLLECTIONCOLUMN/contrast_aperture-group ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/COLLECTIONCOLUMN/field_aperture-group ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/COLLECTIONCOLUMN/mode-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/COLLECTIONCOLUMN/projection-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/COLLECTIONCOLUMN/scheme-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/description-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/DETECTOR-group ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/DETECTOR/amplifier_type-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/DETECTOR/DATA-group ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/DETECTOR/DATA/raw-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/DETECTOR/DATA@signal-attribute ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/DETECTOR/detector_type-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/energy_resolution-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/ENERGYDISPERSION-group ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/ENERGYDISPERSION/energy_scan_mode-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/ENERGYDISPERSION/entrance_slit-group ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/ENERGYDISPERSION/exit_slit-group ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/ENERGYDISPERSION/pass_energy-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/ENERGYDISPERSION/scheme-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/fast_axes-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/ELECTRONANALYSER/slow_axes-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/energy_resolution-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/MANIPULATOR-group ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/MANIPULATOR/drain_current-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/MANIPULATOR/sample_bias-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/MANIPULATOR/sample_temperature-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/SOURCE-group ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/SOURCE/name-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/SOURCE/probe-field ` * :ref:`/NXmpes/ENTRY/INSTRUMENT/SOURCE/type-field ` * :ref:`/NXmpes/ENTRY/PROCESS-group ` * :ref:`/NXmpes/ENTRY/PROCESS/angular_calibration-group ` * :ref:`/NXmpes/ENTRY/PROCESS/angular_calibration/applied-field ` * :ref:`/NXmpes/ENTRY/PROCESS/angular_calibration/calibrated_axis-field ` * :ref:`/NXmpes/ENTRY/PROCESS/energy_calibration-group ` * :ref:`/NXmpes/ENTRY/PROCESS/energy_calibration/applied-field ` * :ref:`/NXmpes/ENTRY/PROCESS/energy_calibration/calibrated_axis-field ` * :ref:`/NXmpes/ENTRY/PROCESS/momentum_calibration-group ` * :ref:`/NXmpes/ENTRY/PROCESS/momentum_calibration/applied-field ` * :ref:`/NXmpes/ENTRY/PROCESS/momentum_calibration/calibrated_axis-field ` * :ref:`/NXmpes/ENTRY/PROCESS/spatial_calibration-group ` * :ref:`/NXmpes/ENTRY/PROCESS/spatial_calibration/applied-field ` * :ref:`/NXmpes/ENTRY/PROCESS/spatial_calibration/calibrated_axis-field ` * :ref:`/NXmpes/ENTRY/SAMPLE-group ` * :ref:`/NXmpes/ENTRY/SAMPLE/atom_types-field ` * :ref:`/NXmpes/ENTRY/SAMPLE/chemical_formula-field ` * :ref:`/NXmpes/ENTRY/SAMPLE/gas_pressure-field ` * :ref:`/NXmpes/ENTRY/SAMPLE/name-field ` * :ref:`/NXmpes/ENTRY/SAMPLE/preparation_date-field ` * :ref:`/NXmpes/ENTRY/SAMPLE/preparation_description-group ` * :ref:`/NXmpes/ENTRY/SAMPLE/sample_history-group ` * :ref:`/NXmpes/ENTRY/SAMPLE/situation-field ` * :ref:`/NXmpes/ENTRY/SAMPLE/temperature-field ` * :ref:`/NXmpes/ENTRY/start_time-field ` * :ref:`/NXmpes/ENTRY/title-field ` * :ref:`/NXmpes/ENTRY/USER-group ` * :ref:`/NXmpes/ENTRY/USER/address-field ` * :ref:`/NXmpes/ENTRY/USER/affiliation-field ` * :ref:`/NXmpes/ENTRY/USER/email-field ` * :ref:`/NXmpes/ENTRY/USER/name-field ` * :ref:`/NXmpes/ENTRY/USER/orcid-field ` **NXDL Source**: https://github.com/nexusformat/definitions/blob/main/contributed_definitions/NXmpes.nxdl.xml